top of page
S200.jpg
Hiwave Ultrasonic Non-destructive Testing System
# S200 - L/S

Details: 

Large Scale Model. 
S200’s Scanning range is 8 – 16 times larger than S100;

Suitable for medium and large-sized parts sampling detection; Equipped with detection routines, the detection efficiency is increased substantially. 
Used for QC during the production process in workshop/ product complete inspection. 

 

Applications:

Vacuum brazing (water-cooled cooling panel), carbon fiber composite materials, large welding sub-assembly of low-voltage electrical apparatus. 

Specification:

1. Rated Control Circuit Voltage (Uc): 220V±10%/50Hz, 3KW 
2. Maximum Scanning Range: S200-S: 900mm×600mm×250mm
                                                           S200-L: 1500mm×1200mm×500mm 
3. Overall Size: S200-S: 1800mm×1300mm×1550mm
                             S200-L: 3000mm×4500mm×2600mm
4. Transducer Frequency: 1~50MHz

     (Standard configuration; Can be upgraded up to 230MHz)
5. Recommended Image Resolution Ratio: 0.5um ~ 4000um;
6. Typical Scanning Time: <60s 

     (Operation condition: 10mm × 10mm, Image resolution ratio: 50um)
7. Maximum Scanning Speed: 500mm/s
    Maximum Scanning Accelerated Velocity: 3m/s²
8. Motion Mechanism Positional Accuracy: 
    Axis X and Y: ±1um         Axis Z: ±10um

    Resetting Positional Accuracy: 
    Axis X and Y: ≤±0.02mm     Axis Z: ≤±0.02mm

9. Sampling Frequency: 25~250MHz;
     (Standard configuration; Can be upgraded up to 1.5GHz)
10. Adjustable Increment of each Channel: -13~66dB

       (Standard configuration; Can be upgraded)
       Pulse Repetition Frequency: 5kHz

       (Standard configuration; Can be upgraded)